OrcaSlicer Settings: PA6-GF
PA6-GF Settings
We are currently testing PA6-GF (Nylon with Glass Fiber reinforcement) and have dialed in some initial settings using OrcaSlicer.
Temperature Settings
Based on our temperature tower tests and material properties:
- Nozzle Temperature: 270°C (Best result from temp tower)
- Bed Temperature: 60°C
- Chamber Temperature: 60°C
Note: The Glass Transition temperature (Tg) of this material is 67°C. Keeping the bed and chamber at 60°C helps prevent warping while staying safely below the Tg to avoid creep or deformation during printing.
Other Notes
- Slicer: OrcaSlicer
- Material: PA6-GF